SIEMENS · SIRIUS 6AG1455
*** spare part *** SIPLUS D455-2 DP/PN based on 6AU1455-2AD00-0AA0 with conformal coating, 0…+55 °C, SIPLUS drive-based Control Unit D455-2 DP/PN; programmable motion control system; ultra-high performance; interfaces: 12 DI, 16 DI/DO, 6 DRIVE-CLiQ, 3 PROFIBUS, 3 PROFINET ports, 3 Ethernet, 2 USB, 2 option slots; including double fan/battery module and battery
Запросить цену в WhatsApp ↗
По запросу
Технические характеристики 6AG1455-2AD00-4AA0
| Параметр | Значение |
|---|---|
![]() | *** spare part *** SIPLUS D455-2 DP/PN based on 6AU1455-2AD00-0AA0 with conformal coating, 0…+55 °C, SIPLUS drive-based Control Unit D455-2 DP/PN; programmable motion control system; ultra-high performance; interfaces: 12 DI, 16 DI/DO, 6 DRIVE-CLiQ, 3 PROFIBUS, 3 PROFINET ports, 3 Ethernet, 2 USB, 2 option slots; including double fan/battery module and battery |
| Сведения об изделии | |
| product brand name | SIPLUS |
| product type designation | D455-2 DP/PN SIPLUS |
| Performance class for motion control system | ULTRA-HIGH Performance |
| Version of the motion control system | Multiple-axis system |
| PLC and motion control performance | |
| number of axes / maximum | 128 |
| Minimum PROFIBUS cycle clock | 1 ms |
| Minimum PROFINET send cycle clock | 0.25 ms |
| Minimum interpolator cycle clock | 0.25 ms |
| Minimum servo cycle clock | 0.25 ms |
| note | 0.125 ms (only with ET 200SP, SCOUT TIA V4.5 or higher and SERVO-FAST) |
| Integrated drive control / header | |
| Maximum number of axes for integrated drive control | |
| servo | 6 |
| vector | 6 |
| V/f | 12 |
| note | Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x/V5.x |
| Memory | |
| RAM (work memory) | 388 Mbyte |
| Additional RAM work memory for Java applications | 20 Mbyte |
| RAM disk (load memory) | 90 Mbyte |
| Retentive memory | 512 kbyte |
| Persistent memory (user data on CF) | 1.5 Gbyte |
| Communication | |
| Interfaces | |
| DRIVE-CLiQ | 6 |
| USB | 2 |
| Industrial Ethernet | 2 |
| PROFIBUS | 2 |
| note | Equidistant and isochronous; Can be configured as master or slave |
| PROFINET | 1 |
| note | 1 interface with 3 ports onboard; 1 interface with 4 ports optional via CBE30-2; functionality: supports PROFINET IO with IRT and RT; configurable as PROFINET IO Controller and/or Device; supports media redundancy (MRP and MRPD) |
| General technical data | |
| Fan | Wert fehlt |
| DC supply voltage | |
| rated value | 24 V |
| minimum | 20.4 V |
| maximum | 28.8 V |
| consumed current / typical | 1 900 mA |
| note | with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
| Making current, typ. | 5 A |
| Power loss, typ. | 46 W |
| Ambient temperature, during | |
| long-term storage | -25 ... +55 °C |
| transport | -40 ... +70 °C |
| operation | 0 ... 55 °C |
| note | Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (12.6 °F) per 1000 m (3281 ft). |
| Relative humidity | |
| during operation | 0 ... 100 % |
| without condensation, tested acc. to IEC 60068-2-38 | condensation/frost permitted (no commissioning in bedewed state) |
| Product property / Conformal coating | Yes |
| Resistance | |
| to biologically active substances, / conformity acc. to EN 60721-3-3 | Yes |
| Note | Class 3B2 mold and fungal spores (except fauna); For operation, the plug covers included in delivery must be left on the unused interfaces! |
| to chemically active substances, / conformity acc. to EN 60721-3-3 | Yes |
| Note | Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation. |
| Air pressure | 620 ... 1 060 hPa |
| Degree of protection | IP20 / UL open type |
| height | 380 mm |
| width | 50 mm |
| depth | 270 mm |
| Depth / Note | When the spacer is removed 230 mm (9.05 in) deep |
| net weight | 4 300 g |
| Digital inputs / header | |
| number of digital inputs | 12 |
| DC input voltage | |
| rated value | 24 V |
| for signal "1" | 15 ... 30 V |
| for signal "0" | -3 ... +5 V |
| Electrical isolation | Yes |
| note | Yes, in groups of 6 |
| Current consumption for "1" signal level, typ. | 9 mA |
| Input delay time for | |
| signal "0" → "1", typ. | 50 µs |
| signal "1" → "0", typ. | 150 µs |
| Digital inputs/outputs / header | |
| Number of digital I/Os | 16 |
| Parameterization possibility of the digital I/Os | can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
| If used as an input / header | |
| DC input voltage | |
| rated value | 24 V |
| for signal "1" | 15 ... 30 V |
| for signal "0" | -3 ... +5 V |
| Electrical isolation | No |
| Current consumption for "1" signal level, typ. | 9 mA |
| Input delay time for | |
| signal "0" → "1", typ. | 5 µs |
| signal "1" → "0", typ. | 50 µs |
| Measuring input / reproducibility | 5 µs |
| Measuring input / resolution | 1 µs |
| If used as an output / header | |
| Load voltage | |
| rated value | 24 V |
| minimum | 20.4 V |
| maximum | 28.8 V |
| Electrical isolation | No |
| Current carrying capacity for each output, max. | 500 mA |
| Leakage current, max. | 2 mA |
| Output delay for | |
| signal "0" → "1", typ. | 150 µs |
| signal "0" → "1", max. | 400 µs |
| signal "1" → "0", typ. | 75 µs |
| signal "1" → "0", max. | 150 µs |
| note | Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
| Cam output | |
| reproducibility | 10 µs |
| resolution | 1 µs |
| Switching frequency of the outputs for | |
| resistive load, max. | 4 kHz |
| inductive load, max. | 2 Hz |
| lamp load, max. | 11 Hz |
| Short-circuit protection | Yes |
| Additional technical data | |
| Back-up of non-volatile data | |
| of retentive data | unlimited buffer duration |
| of real-time clock, min. | 4 d |
| note | longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
| Approvals | |
| USA | cULus |
| Canada | cULus |
| Australia | RCM (formerly C-Tick) |
| Korea | No |
| Russia, Belarus and Kazakhstan | EAC |
Техническая документация по 6AG1455-2AD00-4AA0
- Каталог продукции «SIMATIC S7-400 - контроллер высшего класса»язык: RU, размер: 178.00 Кб
- Обзорный каталог «Программируемые контроллеры S7-400, функциональные модули»язык: RU, размер: 4.27 Мб
- Обзорный каталог «Программируемые контроллеры S7-400»язык: RU, размер: 5.50 Мб
- Каталог продукции «Аппаратура SIPLUS extreme для тяжелых условий эксплуатации»язык: RU, размер: 236.47 Кб
- Каталог продукции «SIMATIC S7-400H - резервированные системы автоматизации»язык: RU, размер: 307.90 Кб
- Каталог продукции «Коммуникационные процессоры PtP и протокол Modbus RTU»язык: RU, размер: 148.33 Кб
- Каталог продукции «FM 355/FM 455 - модули автоматического регулирования»язык: RU, размер: 133.20 Кб
- Каталог продукции «Функциональные модули для систем позиционирования на базе SIMATIC S7-300/S7-400»язык: RU, размер: 562.41 Кб
- Руководство пользователя «Программируемые контроллеры S7-400F и S7-400FH. Системы повышенной безопасности»язык: RU, размер: 5.77 Мб, страниц: 3
- Руководство пользователя «Система автоматизации S7-400 H. Отказоустойчивые системы»язык: RU, размер: 4.81 Мб, страниц: 328
- Руководство пользователя «Система автоматизации S7-400. Данные CPU»язык: RU, размер: 2.28 Мб, страниц: 3
- Руководство по конфигурированию/установке «Программируемые контроллеры S7–400, M7–400»язык: RU, размер: 4.58 Мб, страниц: 9
- Руководство пользователя «Список инструкций системы S7-400. CPU 412, 414, 416, 417»язык: RU, размер: 873.11 Кб, страниц: 3
- Руководство пользователя «Программируемые контроллеры S7-400, M7-400. Данные модулей»язык: RU, размер: 7.76 Мб, страниц: 612
- Руководство по конфигурированию/установке «Система автоматизации S7-400. Руководство по монтажу»язык: RU, размер: 2.47 Мб, страниц: 3
- Обзорный буклет «Системы управления SIMATIC. Обзор продукции »язык: RU, размер: 1.73 Мб
- «A»язык: A, страниц: 100, размер: 4.65 Мб
- IPC_tablet_operating_instructions_en_en-US.pdfстраниц: 26, размер: 1.87 Мб
- Брошюра «SIMATIC S7-1500 плюс TIA Portal. Мощность + эффективность. Безусловный плюс в автоматизации»язык: RU, страниц: 8, размер: 939.67 Кб
- S5-95U.pdfстраниц: 99, размер: 724.37 Кб
- Руководство пользователя «STL для S7-300 и S7-400 - программирование»язык: RU, страниц: 254, размер: 3.98 Мб
- Брошюра «Новые перспективы для большего успеха. Инновационный спектр систем автоматизации simatic»язык: RU, страниц: , размер: 1.74 Мб