Siemens 3RT5065-6AF36 коммутационное устройство

Siemens 3RT5065-6AF36
SIEMENS · SIRIUS 3RT5065

Contactor 110...127 V AC/DC AC3 132 kW 400 V AC (50...60 Hz) / DC operation auxiliary contacts 2 NO + 2 NC, 3-pole, size S10 bar connections conventional operating mechan. screw terminal

Технические характеристики 3RT5065-6AF36

Технические данные Siemens 3RT5065-6AF36
ПараметрЗначение
Siemens 3RT5065-6AF36Contactor 110...127 V AC/DC AC3 132 kW 400 V AC (50...60 Hz) / DC operation auxiliary contacts 2 NO + 2 NC, 3-pole, size S10 bar connections conventional operating mechan. screw terminal
Сведения об изделии
product brand nameSIRIUS
product designationPower contactor
product type designation3RT5
General technical data
size of contactorS10
product extension auxiliary switchYes
power loss [W] for rated value of the current
at AC in hot operating state per pole18 W
without load current share typical7.4 W
type of calculation of power loss current-dependentquadratic
insulation voltage rated value1 000 V
degree of pollution3
surge voltage resistance rated value8 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
shock resistance at rectangular impulse
at AC8,5 g / 5 ms, 4,2 g / 10 ms
at DC8,5 g / 5 ms, 4,2 g / 10 ms
shock resistance with sine pulse
at AC13,4 g / 5 ms, 6,5 g / 10 ms
at DC13,4 g / 5 ms, 6,5 g / 10 ms
mechanical service life (operating cycles)
of contactor typical10 000 000
of the contactor with added auxiliary switch block typical10 000 000
Substance Prohibitance (Date)03/01/2017
SVHC substance nameLead CAS-No. 7439-92-1
Net Weight6.55 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
during operation-25 ... +60 °C
during storage-55 ... +80 °C
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operating voltage
at AC-3 rated value maximum1 000 V
at AC-3e rated value maximum1 000 V
operational current
at AC-1 up to 690 V
at ambient temperature 40 °C rated value330 A
at ambient temperature 60 °C rated value300 A
at AC-3
at 400 V rated value265 A
at 690 V rated value265 A
at AC-3e
at 400 V rated value265 A
at 690 V rated value265 A
at 1000 V rated value95 A
connectable conductor cross-section in main circuit at AC-1
at 60 °C minimum permissible185 mm²
at 40 °C minimum permissible185 mm²
operational current for approx. 200000 operating cycles at AC-4
at 400 V rated value117 A
at 690 V rated value105 A
operating power
at AC-1
at 230 V at 60 °C rated value113 kW
at 400 V at 60 °C rated value197 kW
at 690 V at 60 °C rated value340 kW
at AC-3
at 230 V rated value75 kW
at 400 V rated value132 kW
at 500 V rated value160 kW
at 690 V rated value250 kW
at AC-3e
at 230 V rated value75 kW
at 400 V rated value132 kW
at 500 V rated value160 kW
at 1000 V rated value132 kW
operating power for approx. 200000 operating cycles at AC-4
at 400 V rated value66 kW
at 690 V rated value102 kW
no-load switching frequency
at AC2 000 1/h
at DC2 000 1/h
operating frequency
at AC-1 maximum800 1/h
at AC-3 maximum700 1/h
at AC-3e maximum700 1/h
at AC-4 maximum130 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
at 50 Hz rated value110 ... 127 V
at 60 Hz rated value110 ... 127 V
control supply voltage at DC rated value110 ... 127 V
operating range factor control supply voltage rated value of magnet coil at DC
initial value0.8
full-scale value1.1
operating range factor control supply voltage rated value of magnet coil at AC
at 50 Hz0.8 ... 1.1
at 60 Hz0.8 ... 1.1
design of the surge suppressorwith varistor
apparent pick-up power of magnet coil at AC
at 50 Hz590 VA
at 60 Hz590 VA
inductive power factor with closing power of the coil
at 50 Hz0.9
at 60 Hz0.9
apparent holding power of magnet coil at AC
at 50 Hz6.7 VA
at 60 Hz6.7 VA
inductive power factor with the holding power of the coil
at 50 Hz0.9
at 60 Hz0.9
closing power of magnet coil at DC650 W
holding power of magnet coil at DC7.4 W
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
operational current at AC-12 maximum10 A
operational current at AC-15
at 230 V rated value6 A
at 400 V rated value3 A
operational current at DC-12
at 24 V rated value6 A
at 110 V rated value3 A
at 220 V rated value1 A
operational current at DC-13
at 24 V rated value6 A
at 110 V rated value1 A
at 220 V rated value0.3 A
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value200 hp
Short-circuit protection
design of the fuse link
for short-circuit protection of the main circuit
with type of coordination 1 requiredfuse gL/gG: 500 A
with type of coordination 2 requiredfuse gL/gG: 400 A
for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening method side-by-side mountingYes
fastening methodscrew fixing
height210 mm
width145 mm
depth202 mm
Connections/ Terminals
type of electrical connection
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
type of connectable conductor cross-sections
for auxiliary contacts
finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
Safety related data
product function mirror contact according to IEC 60947-4-1Yes
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
Further information
last modified:4/4/2026
Date 4/8/2026Subject to change without notice © Copyright Siemens 2026

Разрешения и сертификаты

General Product Approval EMV
Maritime application other Environment

Техническая документация по 3RT5065-6AF36

← Все исполнения 3RT5065

Ваша корзина

Оформить заказ

Заказ сохранится в магазине. Войдите в личный кабинет, чтобы видеть историю заказов.